Series Cage Guided Control Valve (electric)

Product overview

Nominal Size:DN40 ~ DN400

Pressure Rating:PN16/25/40/63/100;CL150(PN20)/300(PN50)/600(PN110)

Operateing Temperature:-40℃~ 150℃

Characteristics:Equal percentage, linear, quickly open

Rangeability:50:1

Seat Leakage Class:ANSI B16.104: IV、V、VI

Body Material:WCB/WCC/LCB/LCC;WC6/WC9;CF8/CF8M;4A/5A etc.

Trim Material:630/316/316+ST/316nitriding/316+Ni60/316+WC etc.

Seal Material:PTFE+ graphite v-shaped packing, flexible graphite ring packing, graphite +PTFE braided packing etc.


Product Detail

Adopting a separated sleeve, large area guide structure, and a high-performance non-metallic sealing ring with pressure balance sealing ring. It has the characteristics of good dynamic stability, high control accuracy, large allowable pressure difference, small operating force, and large flow capacity. Suitable for fluid control under normal temperature conditions, large pressure difference, and alternating stress.


The ZAZ type regulating valve consists of two parts: an electric actuator and a regulating valve. The regulating valve has two forms: a single seat and a three-way. The electric actuator bracket is connected to the regulating valve cover with a nut, and the output shaft of the actuator is connected to the valve core and valve stem of the regulating valve as a whole with a clamp block. The regulating valve has two types of functions: electric open and electric close. The initial position of the electric open valve is closed, and after being energized, the valve is opened; The initial position of the electric shut-off valve is open, and after being energized, the valve is closed. A three-way valve, due to the simultaneous opening and closing of the valve, has no distinction between electric opening and electric closing. But because it indicates whether the initial position is for the horizontal pipeline to open or for the vertical pipeline to open. Its principle: The actuator receives switch signals from the regulating instrument, and the output shaft drives the valve core to control the flow of the regulated medium.


Main external dimensions

DN

20

25

32

40

50

65

80

100

125

150

200

φA

177

177

177

226

L

PN16、40

150

160

180

200

230

290

310

350

400

480

600

PN63/160

230

230/250

260

260

300

340

380

430

500

550

650

H1

PN16

53

58

70

75

83

93

100

110

125

143

170

PN40

53

58

70

75

83

93

100

118

135

150

188

PN63

65

70

78

85

90

103

108

125

148

173

208

H

Standard type

567

567

593

605

615

673

693

709

912

965

1058

Heat dissipation type

673

673

703

703

717

755

831

841

1011

1139

1231

Bellows sealed type

643

655

679

727

737

795

878

886

1089

1142

1235

WT (Kg)

10

12

15

17

18

34

46

54

76

79

100




Recommend